Common faults of multi station hot forming machine


Time: 2024-09-13 17:24:09.767

The common faults and solutions of multi station hot forming machines mainly include the following aspects

The common faults and solutions of multi station hot forming machines mainly include the following aspects:

Manual control box malfunction:

Check whether the various parameter settings in the computer are correct.
Open the rear door and inspect a 50A fast recovery diode, as well as check if the 24V square positive/negative conversion relay is damaged or has poor contact.
Check if the third fuse at the lower outlet of the rear door on the side of the electrical cabinet is blown.
Incorrect counting of grating ruler:

Check for damaged parts on the high-power board during discharge arc pulling.
The servo motor head cannot be raised or lowered:

Check whether the operation is correct (such as whether the manual control box and sleep are turned on, whether the emergency stop switch and lock head switch on the electrical cabinet operation board are in the normal position, etc.).
Check if the three indicator lights on the third servo drive board inside the front door of the electrical cabinet are constantly on. If they are not on, then check if the fourth fuse at the outlet under the rear door of the electrical cabinet is blown.
Open the hood of the host and check if the two upper and lower limit switches on top are damaged.
Check if the main processing line (red thick line connected to the machine clamp, black thick line connected to the back seat of the oil tank) has come off.
Discharge without current, no alarm sound when touching the edge:

Check whether the various parameter settings in the computer are correct.
Open the rear door and inspect a 50A fast recovery diode, as well as check if the 24V square positive/negative conversion relay is damaged or has poor contact.
Check if the third fuse at the lower outlet of the rear door on the side of the electrical cabinet is blown.
Hanging cups, burrs, gaps, and other issues:

These faults may be related to factors such as insufficient or blocked mold cooling, damaged upper and lower cutting edges, non-standard mold clamping, mold guide sleeve jamming, wear and tear of upper and lower cutting edges, tight positioning of cutting edges, wear of top cutting block, and lack of temperature adjustment. The solution includes finding the cause of high cooling water temperature and using air to open the blocked water passage; If there is any damage to the upper and lower cutting edges, remove them and replace them; Align the mold with a balance block; Remove the material from the guide sleeve; Remove the cutting edge and grind the cutting edge with a grinder or lathe; Remove the blade and increase the gap between the blade positioning points; Relax the mold; Grind the low top blade block; Adjust the temperature and compare the product with the first piece.
Through the above methods, common faults in multi station hot forming machines can be effectively solved, ensuring the normal operation of the equipment and improving production efficiency.